Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
J Can Assoc Gastroenterol ; 7(2): 149-153, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38596804

RESUMO

Background: The virtual scale endoscope (VSE) helps endoscopists measure colorectal polyp size more accurately compared to visual assessment (VA). However, previous studies were not adequately powered to evaluate the sizing of polyps at clinically relevant size thresholds and relative accuracy for size subgroups. Methods: We created 64 artificial polyps of varied sizes and Paris class morphology, randomly assigned 1:1 to be measured (383 total measurement datapoints with VSE and VA by 6 endoscopists blinded to true size) in a colon model. We added data from two previous trials (480 measurement datapoints). We evaluated for correct classification of polyps into size groups at 3 mm, 5 mm, 10 mm, and 20 mm size thresholds and the relative size measurement accuracy for diminutive polyps (≤5 mm), small polyps (5-9 mm), large polyps at 10-19 mm, and polyps (≥20). Results: VSE had significantly less size group misclassifications at the 5 mm, and 10 mm thresholds (28 percent vs. 45 percent, P = 0.0159 and 26 percent vs. 44 percent, P = 0.0135, respectively). For the 3 mm and 20 mm thresholds, VSE had lower misclassifications; however, this was not statistically significant (36 percent vs. 46 percent, P = 0.3853 and 38 percent vs. 41 percent, P = 0.2705, respectively). The relative size measurement accuracy was significantly higher for VSE compared to VA for all size subgroups (diminutive (P < 0.01), small polyps (P < 0.01), 10-19 mm (P < 0.01), and ≥20 mm (P < 0.01)). Conclusion: VSE outperforms VA in categorizing polyps into size groups at the clinically relevant size thresholds of 5 mm and 10 mm. Using VSE resulted in significantly higher relative measurement accuracy for all size subgroups.

3.
Scand J Gastroenterol ; 59(5): 608-614, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38333956

RESUMO

BACKGROUND AND AIMS: Accurate polyp size estimation during colonoscopy has an impact on clinical decision-making. A laser-based virtual scale endoscope (VSE) is available to allow measuring polyp size using a virtual adaptive scale. This study evaluates video-based polyp size measurement accuracy among expert endoscopists using either VSE or visual assessment (VA) with either snare as reference size or without any reference size information. METHODS: A prospective, video-based study was conducted with 10 expert endoscopists. Video sequences from 90 polyps with known reference size (fresh specimen measured using calipers) were distributed on three different slide sets so that each slide set showed the same polyp only once with either VSE, VA or snare-based information. A slide set was randomly assigned to each endoscopist. Endoscopists were asked to provide size estimation based on video review. RESULTS: Relative accuracies for VSE, VA, and snare-based estimation were 75.1% (95% CI [71.6-78.5]), 65.0% (95% CI [59.5-70.4]) and 62.0% (95% CI [54.8-69.0]), respectively. VSE yielded significantly higher relative accuracy compared to VA (p = 0.002) and to snare (p = 0.001). A significantly lower percentage of polyps 1-5 mm were misclassified as >5 mm using VSE versus VA and snare (6.52% vs. 19.6% and 17.5%, p = 0.004) and a significantly lower percentage of polyps >5 mm were misclassified as 1-5 mm using VSE versus VA and snare (11.4% vs. 31.9% and 14.9%, p = 0.038). CONCLUSIONS: Endoscopists estimate polyp size with the highest accuracy when virtual adaptive scale information is displayed. Using a snare to assist sizing did not improve measurement accuracy compared to displaying visual information alone.


Assuntos
Pólipos do Colo , Colonoscopia , Gravação em Vídeo , Humanos , Estudos Prospectivos , Colonoscopia/métodos , Pólipos do Colo/patologia , Competência Clínica , Masculino , Feminino
4.
Gastroenterology ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331204

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).

5.
Gastrointest Endosc ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38331224

RESUMO

BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large non-pedunculated colorectal polyps are often referred to expert centres for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of our study was to establish minimum expected standards for the referral of LNPCP for potential ER. METHODS: A Delphi methodology was employed to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and three rounds of surveys were conducted to achieve consensus, with quantitative and qualitative data analysed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographics, relevant medications, lesion factors, photodocumentation and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements ranged from 7.04 to 9.29 out of 10, with high percentages of experts considering most statements as a very high priority. Subgroup analysis by continent revealed some variations in consensus rates among experts from different regions. CONCLUSION: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.

8.
Scand J Gastroenterol ; 59(1): 112-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37743643

RESUMO

INTRODUCTION: Serrated lesions (SLs) including traditional serrated adenomas (TSA), large hyperplastic polyps (HP) and sessile serrated lesions (SSLs) are associated with high incomplete resection rates. Margin ablation combined with EMR (EMR-T) has become routine to reduce local recurrence while cold snare polypectomy (CSP) is becoming recognized as equally effective for large SLs. Our aim was to evaluate local recurrence rates (LRR) and the use of margin ablation in preventing recurrence in a retrospective cohort study. METHODS: Patients undergoing resection of ≥15 mm colorectal SLs from 2010-2022 were identified through a pathology database and electronic medical records search. Hereditary CRC syndromes, first follow-up > 18 months or no follow-up, surgical resection were excluded. Primary outcome was LRRs (either histologic or visual) during the first 18-month follow-up. Secondary outcomes were LRRs according to size, and resection technique. RESULTS: 191 polyps in 170 patients were resected (59.8% women; mean age, 65 years). The mean size of polyps was 22.4 mm, with 107 (56.0%) ≥20 mm. 99 polyps were resected with EMR, 39 with EMR-T, and 26 with CSP. Mean first surveillance was 8.2 mo. Overall LRR was 18.8% (36/191) (16.8% for ≥20 mm, 17.9% for ≥30 mm). LRR was significantly lower after EMR-T when compared with EMR (5.1% vs. 23.2%; p = 0.013) or CSP (5.1% vs. 23.1%; p = 0.031). There was no difference in LRR between EMR without margin ablation and CSP (p = 0.987). CONCLUSION: The local recurrence rate for SLs ≥15 mm is high with 18.8% overall recurrence. EMR with thermal ablation of the margins is superior to both no ablation and CSP in reducing LRRs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Idoso , Masculino , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Estudos Retrospectivos , Adenoma/cirurgia , Adenoma/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Ressecção Endoscópica de Mucosa/métodos
9.
Am J Gastroenterol ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38084850

RESUMO

INTRODUCTION: This study aimed to compare the accuracy of polyp size measurements using a virtual scale endoscope (VSE) with an integrated laser-based adaptive scale function and visual assessment (VA) during colonoscopies. METHODS: We conducted a single-blinded, prospective randomized controlled trial. Eligible patients (aged 45-80 years) undergoing screening, surveillance, or diagnostic colonoscopies were randomly assigned (1:1) into 2 groups. In the intervention group, all detected polyps were measured for size using VSE; in the control group, all polyps were measured using VA. Size measurements were compared with a reference standard of digital caliper measurement immediately post polypectomy. The primary outcome was the relative accuracy of real-time VSE measurement compared with VA. Secondary outcomes included the mean differences and the correlations between VSE or VA sizes and the reference standard of measurement. RESULTS: Overall, 230 patients were enrolled and randomized. The relative size measurement accuracy of VSE was 84% in 118 polyps, which was significantly higher than that of VA (105 polyps; 68.4%, P < 0.001). VSE resulted in a significantly higher percentage of size measurements within 25% of true size compared with VA (81.4% vs 41%, P < 0.001). VSE had a significantly lower percentage for >5-mm polyps incorrectly sized as 1-5 mm compared with VA (13.5% vs 57.1%; P < 0.001) and a significantly lower percentage for >3-mm polyps incorrectly sized as 1-3 mm compared with VA (11.3% vs 56.5%; P < 0.001). DISCUSSION: VSE significantly improves the size measurement accuracy of colorectal polyps during colonoscopies compared with VA and results in fewer misclassifications at relevant decision-making size thresholds.

11.
Endosc Int Open ; 11(9): E849-E858, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37942445

RESUMO

Background and study aims The risk of developing total metachronous advanced neoplasia (TMAN) in patients with index serrated lesions (SL) or adenoma with high-grade dysplasia (HGD) is unknown. We evaluated this risk in patients with either HGD, SL < 10 mm or SL ≥ 10 mm at index colonoscopy, who underwent surveillance colonoscopies. Patients and methods This retrospective cohort study evaluated all consecutive patients (n = 2477) diagnosed between 2010 and 2019 with colorectal HGD, SLs < 10 mm or SLs ≥ 10 mm. We excluded patients aged < 45 or > 75 years or those who had inflammatory bowel disease, hereditary colorectal cancer (CRC) syndromes, previous or synchronous CRC, or no follow-up colonoscopy. Descriptive variables were compared using analysis of variance or Pearson chi-squared tests. Multivariate Cox regressions were used to compare the risk of TMAN between the HGD, SL < 10 mm and SL ≥ 10 mm groups. Results Overall, 585 patients (mean age 63 years; 55% male; mean follow-up 3.67 years) were included (226 with SLs < 10 mm, 204 with SLs ≥ 10 mm, 155 with HGD). Compared with SLs < 10 mm, patients with HGD did not have a significantly different rate of TMAN (HR=0.75 [0.39-1.44]) and patients with SLs ≥ 10 mm had a higher rate of TMAN (HR=2.08 [1.38-3.15]). Compared with HGD, patients with SLs ≥ 10 mm had a higher rate of TMAN (HR=1.87 [1.04-3.36]). Conclusions The risk for TMAN was higher for patients with SLs ≥ 10 mm than with HGD or SLs < 10 mm. This risk should be considered when planning surveillance intervals for patients diagnosed with large SLs.

15.
Endosc Int Open ; 11(9): E908-E919, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37810903

RESUMO

Background and study aims An independent observer can improve procedural quality. We evaluated the impact of the observer (Hawthorne effect) on important quality metrics during colonoscopies. Patients and Methods In a single-center comparative study, consecutive patients undergoing routine screening or diagnostic colonoscopy were prospectively enrolled. In the index group, all procedural steps and quality metrics were observed and documented, and the procedure was video recorded by an independent research assistant. In the reference group, colonoscopies were performed without independent observation. Colonoscopy quality metrics such as polyp, adenoma, serrated lesions, and advanced adenoma detection rates (PDR, ADR, SLDR, AADR) were compared. The probabilities of increased quality metrics were evaluated through regression analyses weighted by the inversed probability of observation during the procedure. Results We included 327 index individuals and 360 referents in the final analyses. The index group had significantly higher PDRs (62.4% vs. 53.1%, P =0.02) and ADRs (39.4% vs. 28.3%, P =0.002) compared with the reference group. The SLDR and AADR were not significantly increased. After adjusting for potential confounders, the ADR and SLDR were 50% (relative risk [RR] 1.51; 95%, CI 1.05-2.17) and more than twofold (RR 2.17; 95%, CI 1.05-4.47) more likely to be higher in the index group than in the reference group. Conclusions The presence of an independent observer documenting colonoscopy quality metrics and video recording the colonoscopy resulted in a significant increase in ADR and other quality metrics. The Hawthorne effect should be considered an alternative strategy to advanced devices to improve colonoscopy quality in practice.

16.
Am J Gastroenterol ; 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37713525

RESUMO

INTRODUCTION: Polyp size determination plays an important role in endoscopic decision making and follow-up determination. However, there is a lack of knowledge of endoscopist accuracy for polyp sizing and efficacy of available tools for size measurement. Our aim was to compare the accuracy of visual assessment, snare, forceps, and virtual scale endoscope (VSE) in estimating polyp size among a diverse group of endoscopists. METHODS: We conducted a prospective video-based study. One hundred twenty polyps measured and recorded along with all available measurement tools were randomized to visual assessment, snare, forceps, or VSE group. Eleven endoscopists conducted video-based measurement using the randomized measurement tool. Primary outcome was relative accuracy in polyp size measurement compared with caliper measurement immediately postresection. RESULTS: One thousand three hundred twenty measurements were performed. VSE had statistically significantly higher relative accuracy when compared to forceps (79.3 vs 71.3%; P < 0.0001). Forceps had statistically significantly higher relative accuracy when compared to visual assessment (71.3 vs 63.6%; P = 0.0036). There was no statistically significant difference when comparing visual assessment and snare-based measurements (63.6 vs 62.8%; P = 0.797). Overall, 21.5% of polyps >5 mm were misclassified as ≤5 mm and 17.3% of polyps ≥10 mm were misclassified as <10 mm. VSE had the lowest percentage of polyps >5 mm misclassified as ≤5 mm (2.6%), polyps ≤5 mm misclassified as >5 mm (5.1%), and polyps <10 mm misclassified as ≥10 mm (1.7%). DISCUSSION: Visual size estimation of polyps is inaccurate independently of training level, sex, and specialty. Size measurement accuracy can be improved using forceps and yields the highest relative accuracy when an adaptive scale technology is used.

19.
J Can Assoc Gastroenterol ; 6(3): 97-105, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37273970

RESUMO

Background and Aims: Artificial intelligence-aided colonoscopy significantly improves adenoma detection. We assessed the cost-effectiveness of the GI Genius technology, an artificial intelligence-aided computer diagnosis for polyp detection (CADe), in improving colorectal cancer outcomes, adopting a Canadian health care perspective. Methods: A Markov model with 1-year cycles and a lifetime horizon was used to estimate incremental cost-effectiveness ratio comparing CADe to conventional colonoscopy polyp detection amongst patients with a positive faecal immunochemical test. Outcomes were life years (LYs) and quality-adjusted life years (QALY) gained. The analysis applied costs associated with health care resource utilization, including procedures and follow-ups, from a provincial payer's perspective using 2022 Canadian dollars. Effectiveness and cost data were sourced from the literature and publicly available databases. Extensive probabilistic and deterministic sensitivity analyses were performed, assessing model robustness. Results: Life years and QALY gains for the CADe and conventional colonoscopy groups were 19.144 versus 19.125 and 17.137 versus 17.113, respectively. CADe and conventional colonoscopies' overall per-case costs were $2990.74 and $3004.59, respectively. With a willingness-to-pay pre-set at $50,000/QALY, the incremental cost-effectiveness ratio was dominant for both outcomes, showing that CADe colonoscopy is cost-effective. Deterministic sensitivity analysis confirmed that the model was sensitive to the incidence risk ratio of adenoma per colonoscopy for large adenomas. Probabilistic sensitivity analysis showed that the CADe strategy was cost-effective in up to 73.4% of scenarios. Conclusion: The addition of CADe solution to colonoscopy is a dominant, cost-effective strategy when used in faecal immunochemical test-positive patients in a Canadian health care setting.

20.
Endosc Int Open ; 11(5): E480-E489, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206693

RESUMO

Background and study aims Incomplete resection of 4- to 20-mm colorectal polyps occur frequently (> 10 %), putting patients at risk for post-colonoscopy colorectal cancer. We hypothesized that routine use of wide-field cold snare resection with submucosal injection (CSP-SI) might reduce incomplete resection rates (IRRs). Patients and methods Patients aged 45 to 80 years undergoing elective colonoscopies were enrolled in a prospective clinical study. All 4- to 20-mm non-pedunculated polyps were resected using CSP-SI. Post-polypectomy margin biopsies were obtained to determine IRRs through histopathology assessment. The primary outcome was IRR, defined as remnant polyp tissue found on margin biopsies. Secondary outcomes included technical success and complication rates. Results A total of 429 patients (median age 65 years, 47.1 % female, adenoma detection rate 40 %) with 204 non-pedunculated colorectal polyps 4 to 20 mm removed using CSP-SI were included in the final analysis. CSP-SI was technical successful in 97.5 % (199/204) of cases (5 conversion to hot snare polypectomy). IRR for CSP-SI was 3.8 % (7/183) (95 % confidence interval [CI] 2.7 %-5.5 %). IRR was 1.6 % (2/129), 16 % (4/25), and 3.4 % (1/29) for adenomas, serrated lesions, and hyperplastic polyps respectively. IRR was 2.3 % (2/87), 6.3 % (4/64), 4.0 % (6/151), and 3.1 % (1/32) for polyps 4 to 5 mm, 6 to 9 mm, < 10 mm, and 10 to 20 mm, respectively. There were no CSP-SI-related serious adverse events. Conclusions Use of CSP-SI results in lower IRRs compared to what has previously been reported in the literature for hot or cold snare polypectomy when not using wide-field cold snare resection with submucosal injection. CSP-SI showed an excellent safety and efficacy profile, however comparative studies to CSP without SI are required to confirm these results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...